Даташит moc3041 pdf ( datasheet )

MOC3041 Datasheet Download — ETC

Номер произв MOC3041
Описание OPTICALLY COUPLED BILATERAL SWITCH LIGHT ACTIVATED ZERO VOLTAGE CROSSING TRIAC
Производители ETC
логотип  
1Page

No Preview Available !

MOC3040, MOC3041, MOC3042, MOC3043
MOC3040X, MOC3041X, MOC3042X, MOC3043X
OPTICALLY COUPLED BILATERAL
SWITCHLIGHTACTIVATED ZERO
VOLTAGE CROSSING TRIAC
‘X’ SPECIFICATION APPROVALS

l VDE 0884 in 3 available lead form : —

— STD
— G form

— SMD approved to CECC 00802

DESCRIPTION
The MOC304_ Series are optically coupled
isolators consisting of a Gallium Arsenide
infrared emitting diode coupled with a mono-
lithic silicon detector performing the functions
of a zero crossing bilateral triac mounted in a
standard 6 pin dual-in-line package.
FEATURES

l Options :-

10mm lead spread — add G after part no.
Surface mount — add SM after part no.
Tape&reel — add SMT&R after part no.

l High Isolation Voltage (5.3kV ,7.5kV )

RMS
PK

l Zero Voltage Crossing

l 400V Peak Blocking Voltage

l All electrical parameters 100% tested

l Custom electrical selections available

APPLICATIONS

l CRTs

l Power Triac Driver

l Motors

l Consumer appliances

l Printers

OPTION SM
SURFACE MOUNT
OPTION G
7.62

2.54 Dimensions in mm

1
7.0

6.0 2

3
1.2
7.62
6.62 4.0
3.0
3.0
0.5
0.5
3.35
7.62
0.26
6
5
4
13°
Max
ABSOLUTE MAXIMUM RATINGS
(25 °C unless otherwise noted)
Storage Temperature

-55C — +150C

Operating Temperature

-40C — +100C

Lead Soldering Temperature

260C

(1.6mm from case for 10 seconds)
INPUTDIODE
Forward Current
50mA
Reverse Voltage
6V
Power Dissipation
120mW

(derate linearly 1.41mW/C above 25C)

OUTPUT PHOTO TRIAC
Off-State Output Terminal Voltage 400V
Forward Current (Peak)
1A
Power Dissipation
150mW

(derate linearly 1.76mW/C above 25C)

0.6
0.1
10.46
9.86
1.25
0.75
0.26
10.16
POWERDISSIPATION
Total Power Dissipation
250mW

(derate linearly 2.94mW/C above 25C)

ISOCOMCOMPONENTSLTD
Unit 25B, Park View Road West,
Park View Industrial Estate, Brenda Road
Hartlepool, TS25 1YD England Tel: (01429)863609
Fax : (01429) 863581 e-mail sales@isocom.co.uk

Home


28/3/03
ISOCOM INC
1024 S. Greenville Ave, Suite 240,
Allen, TX 75002 USA
Tel:(214)495-0755 Fax:(214)495-0901
e-mail info@isocom.com

Home


DB91048m-AAS/A6

No Preview Available !

ELECTRICAL CHARACTERISTICS ( T = 25°C Unless otherwise noted )
A
PARAMETER
MIN TYP MAX UNITS
TEST CONDITION
Input
Output
Forward Voltage (V )
F

Reverse Current (IR)

Peak Off-state Current ( I )
DRM

Peak Blocking Voltage ( VDRM )

On-state Voltage ( VTM )

Critical rate of rise of
off-state Voltage ( dv/dt )
1.2 1.4 V

10 µA

500 nA
400 V
3.0 V
600 1500

V/µs

I = 20mA
F

VR = 6V

V = 400V (note 1 )
DRM
I = 500nA
DRM

ITM = 100mA ( peak )

Coupled

Input Current to Trigger ( IFT )(note 2 )

MOC3040
MOC3041
MOC3042
MOC3043
30 mA
15 mA
10 mA
5 mA

VTM = 3V ( note 2 )

Holding Current , either direction ( IH )

Input to Output Isolation Voltage VISO

400
5300
7500

µA

VRMS

V
PK
See note 3
See note 3
Zero
Crossing
Charact-
-eristic
Inhibit Voltage ( V )
IH

Leakage in Inhibited State ( IS )

20 V
500 mA
I = Rated I
F FT
MT1-MT2 Voltage
above which device
will not trigger

IF= Rated IFT

V = Rated V
DRM
DRM
Off-state
Note 1. Test voltage must be applied within dv/dt rating.
Note 2. Guaranteed to trigger at an I value less than or equal to max. I , recommended I lies
F FT F

between Rated IFT and absolute max. IF .

Note 3. Measured with input leads shorted together and output leads shorted together.
28/3/03
DB91048m-AAS/A6

No Preview Available !

CHARACTERISTIC CURVES

Fig.1 Forward Current vs.
Ambient Temperature
60
50
40
30
20
10

-40 -20 0 20 40 60 80 100 120

Ambient temperature Ta (oC)

Fig.3 Minimum Trigger Current
vs. Ambient Temperature
10

VP= 6V

RL= 100

8
6
4
2

20 40 60 80 100

Ambient temperature ( oC)

Fig.5 On-state Voltage vs. Ambient
Temperature
3.0

ITM= 100mA

2.6
2.2
1.8
1.4
1.0
20
40 60 80 100

Ambient temperature Ta ( o C)

Fig.2 On-state Current vs. Ambient
Temperature
0.10
0.05

-40 -20 0 20 40 60 80 100 120

Ambient temperature Ta (oC)

Fig.4 Forward Current vs. Forward
Voltage
100

80oC

100oC

10

60oC

40 oC

20oC

1
0.4 0.8 1.2 1.6 2.0

Forward voltage VF (V)

Fig.6 Holding Current vs.
Ambient Temperature
1

VP= 6V

0.1
0.01
20
40 60 80

Ambient Temperature Ta ( oC)

100
28/03/03
DB91048m-AAS/A6

Всего страниц 4 Pages
Скачать PDF

Related Datasheets

Номер в каталоге Описание Производители
MOC3040 OPTICALLY COUPLED BILATERAL SWITCH LIGHT ACTIVATED ZERO VOLTAGE CROSSING TRIAC ETC
MOC3041 6-Pin DIP Zero-Cross Optoisolators Triac Driver Output Motorola
MOC3041 OPTICALLY COUPLED BILATERAL SWITCH LIGHT ACTIVATED ZERO VOLTAGE CROSSING TRIAC ETC
MOC3041M 6-PIN DIP ZERO-CROSS OPTOISOLATORS TRIAC DRIVER OUTPUT Fairchild Semiconductor
Номер в каталоге Описание Производители
6MBP200RA-060

Intelligent Power Module

Fuji Electric
ADF41020

18 GHz Microwave PLL Synthesizer

Analog Devices
AN-SY6280

Low Loss Power Distribution Switch

Silergy
DataSheet26.com    |    2020    |   Контакты    |    Поиск  

Схема подключения активной нагрузки к оптосимистору

В этой схеме имеется два компонента, которые необходимо вычислить, но фактически подобные расчеты параметров выполняются не всегда. Но все, же приведем эти расчеты параметров для информации.

Расчет параметра резистора RD . Вычисление сопротивления данного резистора влияет от наименьшего прямого тока ИК светодиода, обеспечивающего открытие симистора. Таким образом,

Допустим, для схемы с транзисторным контролем (которое применяется довольно часто в схемах регуляторов температуры), имеющим питания 12В и напряжение на открытом транзисторе (Uкэ) 0,3 В; VDD = 11,7 B и следовательно диапазон If приблизительно равен 15мА для MOC3041.

Необходимо сделать If = 20 мА с учетом понижения эффективности свечения светодиода в течении срока службы (добавить 5 мА) получаем:

RD=(11,7В — 1,5В)/0,02А = 510 Ом.

Расчет параметра сопротивления R . Управляющий электрод оптосимистора может выдержать определенный максимальный ток. Увеличение данного параметра выводит из строя оптрон. Следовательно, нужно вычислить сопротивление, чтобы при наибольшем напряжении сети (к примеру, 220 В) ток не был больше максимально допустимого параметра.

Для примера возьмем максимально-допустимый ток в 1А, тогда сопротивление будет равно:

R=220 В * 1,44 / 1 А = 311 Ом.

Нужно иметь в виду, что слишком большое сопротивление данного резистора может оказать нарушение в стабильности включения оптосимистора.

Расчет параметра сопротивления Rg . Резистор Rg подключается, только если электрод симистора имеет повышенную чувствительность. Как правило, сопротивление Rg находится в диапазоне от 100 Ом до 5 кОм. Желательно применять 1 кОм.

В случае если в управляемой нагрузке есть индуктивная составляющая, то необходимо применять другую схему подключения с защитой силового симистора и оптосимистора.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Adblock